Bang&Clean®   Bang&Clean® Technologies AG  
   
 
 

BANG&CLEAN®

Cleaning with dosed gas explosions

A lance with forced cooling is introduced into the boiler near the clogged area. At the end of the lance a balloon is inflated with an explosive gas mixture. The gas mixture is ignited via remote control ignition.

The explosion results in shock waves which cause the boiler-walls and -tubes to vibrate. The shock waves plus the vibrations will make the build ups / ashes come off the boiler surface.

SAFETY 

  • Equipment is CE conform

  • Safety measures and -procedures have strict rules for highest safety

  • No risk for damaging of boiler tubes (even if explosion bags touches the tubes or walls!)

  • No transportation, storage or use of explosives

  • Gas mixture prepared just before explosion takes place

  • Even if system should fail, process runs into safe conditions. System equipped with safety interlocking (fail safe)

  • Optimal personal protection (Hard hat, goggles, dust mask, ear protection, safety shoes, face protection shield, fire proof working cloth)

APPLICATION REQUIREMENTS: 

  • Openings (in boiler / vessel)
    to reach the areas to be cleaned

  • Free space
    for lance introduction a minimum space in front of each opening is required

  • Infrastructure on site
    pressurized air (4 to 8 bar), water (4 to 8 bar), power 240V (115V)


EXPERIENCE / RECOMMENDATIONS 

  • Cleaning intervals:
    between 4 weeks and 6 month
    Basically determined by boiler design, waste composition and operating conditions.

  • Remark:
    Boiler ashes in combination with humidity (from ambient air or steam) tend to form hard deposits.

    To avoiding these formations we do recommend to clean the boiler in hot conditions: during operation or during the shut-down of the plant.
 
 